SNOOP Monitoring Categories
General
Start of Run Checks
- Link to “neutrino report cards”
* Neutrino report card: per run pass/fail for status tests: Run mask (!&UC), crate mask, trigger mask, trigger thresholds, pulser enabled, pedestals disabled, percent of nhit triggers per crate, blind flasher check, trigger on/hv off check, event rate, pulse gt rate, orphan count, no zero occ normal/owl/butt/neck paddle cards, inter`event timing, clock drift, cgt/cmos errors, lgi select errors
Run Statistics
Summary
- Duration
- Events analyzed
- Orphans
- lone orphans*
- owl/neck/butt events*
- event rate*
- dispatch rate
Trigger Settings (table)
- Masked in
- Threshold
- Zero
- Zero diff
- Alarm zero
- Alarm zero diff
NHIT statistics
- Mean*
- Count nhit < 30*
- Count nhit >= 30*
- Mean orphan nhit
Triggers (table)
- ID
- Name
- Number
- Short frac/rate/mean/rms
- Run frac/rate/mean/rms
Derived trigger stats
- N100M/PULSEGT
- ESHI/PULSEGT
Solar neutrino flux
- CC: short/run/units
- ES: short/run/units
- NC: short/run/units
- Solar core temp: short/run/units
Event pathologies (table)
- Rows: Sharkfin, flasher, neck, junk, elecpickup, muon, muonfollower, lightwater, unidentified h/m/l, burst
- Short count, rate, mean nhit, percent
- Run count, rate, mean nhit, percent
Analog Measurement Board
- All data: differential (mean), integral (mean), peak (mean)
- PGT: differential (mean), integral (mean), peak (mean)
- Nhit > 30 && !ESUMHI: (integral`integral pedestal)/nhits, (peak`peak pedestal)/nhits
Timing and CMOS
- Mean 10MHz vs 50MHz inter`event timing difference
- Peak 10MHz vs 50MHz clock drift
- Count of consecutive event pairs < 410 ns apart
- Count of CGT SYNC CLEAR 16 errors
- Count of CGT SYNC CLEAR 24 errors
- Count of CMOS SYNC CLEAR 16 errors
- Count of PMT LGI SELECT errors
DQXX
- File, date
- Sequencers enabled (value out of total)
- 20ns triggers enabled
- 100ns triggers enabled
- HV resistors pulled
- HV cables pulled
- Channels not operational
- Relays enabled
- OWL/BUTT/NECK relays enabled
Occupancy
- Mean/low/high occupancy: short/med/run
- Total/normal tubes: short/med/run
- Zero/low/high occupancy tubes: short/med/run
- Zero occupancy PCs
- Zero occupancy NECK/OWL/BUTTs
- Zero occupancy BUTT/OWL PCs
- Crate occupancies (short)
Charge distribution plots
- Links to QHS, QHL, QLX, T plots
NHIT Trigger Monitor
- NHIT100MED: number, timestamp
- NHIT100HI: number, timestamp
- NHIT20: number, timestamp
Data Flow
- Current run
- UGND: date, last file on disk, last transferred AG, tape ID, last to tape, tape usage
- AGND: date, last file on disk, last transferred to surf, tape ID, last to tape, tape usage